From cdfba3650865e3936c50d1043ee02389705b25b3 Mon Sep 17 00:00:00 2001
From: Guillem Jover <guillem@hadrons.org>
Date: Fri, 14 May 2010 01:35:55 +0200
Status: applied
Subject: [PATCH 1/2] hwmon: (f75375s) Shift control mode to the correct bit position

The spec notes that fan0 and fan1 control mode bits are located in bits
7-6 and 5-4 respectively, but the FAN_CTRL_MODE macro was making the
bits shift by 5 instead of by 4.

Signed-off-by: Guillem Jover <guillem@hadrons.org>
---
 drivers/hwmon/f75375s.c |    2 +-
 1 files changed, 1 insertions(+), 1 deletions(-)

diff --git a/drivers/hwmon/f75375s.c b/drivers/hwmon/f75375s.c
index 0f58ecc..e5828c0 100644
--- a/drivers/hwmon/f75375s.c
+++ b/drivers/hwmon/f75375s.c
@@ -79,7 +79,7 @@ enum chips { f75373, f75375 };
 #define F75375_REG_PWM2_DROP_DUTY	0x6C
 
 #define FAN_CTRL_LINEAR(nr)		(4 + nr)
-#define FAN_CTRL_MODE(nr)		(5 + ((nr) * 2))
+#define FAN_CTRL_MODE(nr)		(4 + ((nr) * 2))
 
 /*
  * Data structures and manipulation thereof
-- 
1.7.1